300K Solutions

FLOW CYTOMETRY CALIBRATION PARTICLES

The SPHERO Calibration Particles are designed for routine calibration of flow cytometers. By using these particles, the sensitivity and linearity of the system can be determined. The sensitivity of the instrument will help detect any dye or light contamination. The linearity of the instrument will determine if the logarithmic amps and PMTs are functioning properly.

SPHERO Rainbow Calibration Particles

– Contains a mixture of fluorophores that enable the Rainbow Calibration Particles to be excited at any wavelength from 365 nm to 650 nm.
– Allows the calibration of the FITC, PE, PE-TR, PE-Cy5, and APC channels in the flow cytometer with the same set of particles.
– Consists of set of several similar size particles with different fluorescence intensities in a convenient dropper bottle.
– Can be stored in the freezer and reused later since they can withstand repeated freezing and thawing.

Catalog No.DescriptionConcentrationNominal SizePackage Size
RCP-05-5Rainbow Calibration Particles, 4 peaks107/mL0.4-0.6 µm5 mL
RCP-20-5Rainbow Calibration Particles, 4 peaks107/mL1.8-2.2 µm5 mL
RCP-30-5 (6 peaks)Rainbow Calibration Particles, 6 peaks107/mL3.0-3.4 µm5 mL
RCP-30-5A (8 peaks)Rainbow Calibration Particles, 8 peaks107/mL3.0-3.4 µm5 mL
RCP-30-20ARainbow Calibration Particles, 8 peaks107/mL3.0-3.4 µm20 mL
RCP-30-5A-2Rainbow Calibration Particles, 2nd peak from the 8 peak set107/mL3.0-3.4 µm5 mL
RCP-32-5Rainbow Calibration Particles, 6 peaks107/mL3.2 (+/- 0.1) µm5 mL
RCP-35-5Rainbow Calibration Particles, 4 peaks107/mL3.5-4.0 µm5 mL
RCP-60-5Rainbow Calibration Particles, 6 peaks107/mL6.0-6.4 µm5 mL
RCP-60-20Rainbow Calibration Particles, 6 peaks107/mL6.0-6.4 µm20 mL
RQC-30-5Rainbow QC Calibration Particles, 3 peaks2x107/mL3.0-3.4 µm5 mL

SPHERO Rainbow Calibration Particles (Euroflow)

Catalog No.DescriptionConcentrationNominal SizePackage Size
RCP-30-5A (Euroflow)Rainbow Calibration Particles, 8 peaks, Lot EAL01107/mL3.0-3.4 µm5 mL

SPHERO Ultra Rainbow Calibration Particles

– Designed for routine calibration of the flow cytometer in all channels.
– Contain a mixture of fluorophores that enable the optimization of linearity, sensitivity, and resolution of the flow cytometer.
– Especially useful in the Far Red and Violet channels.

Catalog No.DescriptionConcentrationNominal SizePackage Size
URCP-38-2KUltra Rainbow Calibration Kit, 6 peaks
107/mL after mixing3.8 µm (+/- 0.2 µm)1x3 mL
1x2 mL
URCP-38-20KUltra Rainbow Calibration Kit, 6 peaks
107/mL after mixing3.8 µm (+/- 0.2 µm)1x30 mL
1x20 mL
URCP-50-2KUltra Rainbow Calibration Kit, 6 peaks
107/mL after mixing5.0-5.4 µm1x3 mL
1x2 mL
URCP01-30-10KUltra Rainbow Calibration Particle Kit, 3 peaks106/mL3.0-3.4 µm10x3 mL
URCP-100-2Ultra Rainbow Calibration Particles, 6 peaks107/mL8.0-12.9 µm2 mL
URCP-100-2HUltra Rainbow Calibration Particles, 9 peaks107/mL8.0-12.9 µm2 mL
URCP-100-6KUltra Rainbow Calibration Kit, 6 peaks107/mL after mixing8.0-12.9 µm6x2 mL

SPHERO Spectral Matching Calibration Particle Kits

– Surface labeled polystyrene particles with commonly used fluorophores.
– Used to determine the linearity of the logarithmic amps and sensitivity of flow cytometers in specific channels.
– Supplied as individual products for use in specific channels of flow cytometers.

Catalog No.DescriptionConcentrationNominal SizePackage Size
ECFP-F1-5KFITC Easy Calibration Kit, 5 peaks2x106/mL3.0-3.4 µm5x1 mL
ECFP-F2-5KPE Easy Calibration Kit, 5 peaks2x106/mL3.0-3.4 µm5x1 mL
ECFP-F9-6KGFP Easy Calibration Kit, 6 peaks2x106/mL3.0-3.4 µm6x1 mL

SPHERO Rainbow Linear Calibration Particles

Catalog No.DescriptionConcentrationNominal SizePackage Size
RLP-30-5Rainbow Linear Calibration Particles (For use in Linear Scale)107/mL3.0-3.4 µm5 mL

SPHERO APC Calibration Particles

Catalog No.DescriptionConcentrationNominal SizePackage Size
ACP-30-5KAPC Calibration Particle Kit (6 peaks)107/mL3.0-3.4 µm2x5 mL

SPHERO IR Calibration Particles

Catalog No.DescriptionConcentrationNominal SizePackage Size
FCP-34800-6KFluorescent Calibration Particles, 800nm EM, 6 peaks107/mL3.5 µm (+/- 0.2 µm)6x1 mL