300K Solutions

FINE TUNING CELL SORTERS

Flow Cytometry Particles for Fine Tuning Cell Sorters

SPHERO Drop Delay Calibration Particles

– Particles for fine tuning cell sorters that have the appriopriate attachment
– Used to determine the drop delay value
– Improves the accuracy and productivity while sorting

Catalog No.DescriptionConcentrationNominal SizePackage Size
DDCP-70-2Drop Delay Calibration Particles108/mL6.0-8.0 µm2 mL
DDCP-70-20Drop Delay Calibration Particles108/mL6.0-8.0 µm20 mL

SPHERO AccuCount Ultra Rainbow Fluorescent Drop Delay Calibration for Large Cell Sorting

– Large beads for fine tuning cell sorters that have the appropriate attachment
– Used to determine the Drop-Charge Delay (DCD) and Laser Time Delays (LTD) during larger cell sorting
– Used to determine if the flow of larger particles is unaffected by instrument design
– Allow for the real-time correction of instrumentation variation when sorting large cells between 20-30 µm

Catalog No.DescriptionConcentrationNominal SizePackage Size
ACURFP50-70-1AccuCount UltraRainbow Calibration Particles5x107/mL7.0 µm (+/-1 µm)1 mL
ACURFP20-100-1AccuCount UltraRainbow Calibration Particles2x107/mL10.0 µm (+/-1 µm)1 mL
ACURFP5-150-1AccuCount UltraRainbow Calibration Particles5x106/mL15.0 µm (+/-2 µm)1 mL
ACURFP5-200-1AccuCount UltraRainbow Calibration Particles5x106/mL20.0 µm (+/-2 µm)1 mL
ACURFP5-200-5AccuCount UltraRainbow Calibration Particles5x106/mL20.0 µm (+/-2 µm)5 mL
ACURFP2.5-250-1AccuCount UltraRainbow Calibration Particles2.5x106/mL25.0 µm (+/-2 µm)1 mL
ACURFP2.5-250-5AccuCount UltraRainbow Calibration Particles2.5x106/mL25.0 µm (+/-2 µm)5 mL
ACURFP2.5-300-1AccuCount UltraRainbow Calibration Particles2.5x106/mL30.0 µm (+/-2 µm)1 mL
ACURFP2.5-300-5AccuCount UltraRainbow Calibration Particles2.5x106/mL30.0 µm (+/-2 µm)5 mL

SPHERO AccuCount Fluorescent Drop Delay Calibration Particles for Large Cell Sorting

– Large beads for fine tuning cell sorters that have the appropriate attachment
– Used to determine the Drop-Charge Delay (DCD) and Laser Time Delays (LTD) during larger cell sorting
– Labeled with a different fluorophore, Nile Red, than the AccuCount Ultra Rainbow Fluorecent Drop Delay Calibration Particles for Large Cell Sorting, but with matching diameters and concentration
– Allow for the real-time correction of instrumentation variation when sorting large cells between 20-30 µm

Catalog No.DescriptionConcentrationNominal SizePackage Size
ACFP50-7056-1AccuCount Fluorescent Particles5x107/mL7.0 µm (+/-1 µm)1 mL
ACFP20-10056-1AccuCount Fluorescent Particles2x107/mL10.0 µm (+/-1 µm)1 mL
ACFP5-15056-1AccuCount Fluorescent Particles5x106/mL15.0 µm (+/-2 µm)1 mL
ACFP5-20056-1AccuCount Fluorescent Particles5x106/mL20.0 µm (+/-2 µm)1 mL
ACFP2.5-25056-1AccuCount Fluorescent Particles2.5x106/mL25.0 µm (+/-2 µm)1 mL
ACFP2.5-30056-1AccuCount Fluorescent Particles2.5x106/mL30.0 µm (+/-2 µm)1 mL